|
|
|
ILS Max - Industrial Laundry System Maximum*
|
|

|
The ILS Max is a state-of-the-art liquid chemical feed and data management system for
large washers (typically in the 100-1000 lb range)and tunnel systems. It is a modular system, capable of serving up to 15 washer extractors (depending on washer
capacity), delivering up to ten products to each washer. The ILS Max can be configured to operate with any continuous-batch washer with our easy-to-install
Tunnel Kit. Performance/safety benefits include automatic calibration, out-of-chemical alarms, proof-of-flow/proof-of-delivery, code-compliant break tank and a pump
interlock relay ladder to prevent mixing of incompatible chemicals.
*Available in USA only.
|
|
Manual |Brochure |Installation Instructions|ManageNet Manual Pump Spares
Get Acrobat Reader
|

|
Installation Materials
|
Code #
|
Description
|
|
041318
|
Cable Ties, Small
|
|
041319
|
Cable Ties, Large
|
|
051666
|
Check Valve, Siphon Breaker, Optional
|
|
018034
|
Alpha Bus Cable, 4 Conductor, 22 AWG (CSA 0.35MM2)
|
|
051373
|
Cable, 2 conductor, 16 AWG
|
|
057279
|
Enclosure, NEMA Type 1 (IP10)
|
|
041908*
|
Fitting, ELL, 1/2" MPT X 1/2" Tube
|
|
041909*
|
Fitting, ELL 1/2" MPT x 5/8" Tube
|
|
020947
|
Fitting, Barbed, 3/4"
|
|
041933*
|
Fitting, Straight, 1/2" MPT x 1/2" Tube
|
|
041934
|
Fitting, 1/2" MPT x 5/8" Tube
|
|
057039
|
Fitting, Tee, 1/2" x 1/2" x 1/2" Tube
|
|
041305
|
Hose Clamp
|
|
043628
|
Velcro Hook, 2" Wide
|
|
043762
|
Vlecro Loop, 2" Wide
|
* Some combination of these parts is required to provide connection of tube to the POD cell and from the POD cell to the washer.
Two fittings per washer are typical. The size, 1/2" or 5/8", is determined by the size of the transport tube serving the particular washer.
See parts list for contents of installation kit.
|
|
Installation Kit Contents (P/N 056745)
|
Code #
|
Description
|
qty in Kit
|
|
056745
|
Installation kit
|
|
|
051152
|
Back Flow Tee Assembly
|
1 each
|
|
051284
|
Bushing, 2 1/4" Diameter, Plastic, Black
|
1 each
|
|
041248
|
Bushing, Snap, 7/8" O.D. x 11/16" I.D.
|
2 each
|
|
041747
|
Cable, 2 Cond., 22 Gauge
|
12 Feet
|
|
051153
|
Clip, Adh Back, 3/8" Diameter, Plastic
|
10 each
|
|
035514
|
Clamp, Hose, 1 1/32" x 1/ 3/16" Nylon
|
5 each
|
|
057410
|
Hole Plug, 1.00, Nylon
|
1 each
|
|
041235
|
Hole Plug, Plastic, 7/8"
|
2 each
|
|
041972
|
Hose, Washer Hookup, 1/2" x 10 feet
|
1 each
|
|
059275
|
Instruction, Lock Switch Assembly
|
1 each
|
|
056746
|
Manifold, Main
|
1 each
|
|
099921
|
Manifold, POF
|
1 each
|
|
014515
|
Bushing, 1/2" FPT X 3/4" MPT, Brass
|
1 each
|
|
041952
|
Nipple, Hex, 3/8" MPT X 1/2" MPT, Brass
|
1 each
|
|
050579
|
Rail, Mounting, 34", Stainless Steel
|
1 each
|
|
040987
|
Screw, Panhead, 10-32 x 1/2", Stainless Steel
|
10 each
|
|
051150
|
Chemical Uptake Assembly, 3/4" x 46" Long
|
6 each
|
|
041772
|
Tubing, LDPE, 1/4" O.D., White
|
10 feet
|
|
055702
|
Tubing, Silicone, 0.750 I.D. x 0.125 W, Trans.
|
3 feet
|
|
042757
|
Terminal Block SCR, 3 x 1, Cable, Phoenix
|
1 each
|
|
042000
|
Bulkhead Fitting, VP, 1/4" Tube
|
1 each
|
|
041151
|
Washer, Hose Adapter, 3/4"
|
2 each
|
|
|
Accessory Kits
|
Code #
|
Description
|
|
051150
|
Chemical Standpipe (drum lances) (6 each supplied in Installation Kit)
|
|
020956
|
Alarm Annunciator (Audible
|
|
059430
|
Alarm Beacon, Red
|
|
096448
|
Strobe Light, Amber 12/24 VAC/DC
|
|
1202252
|
USB/RS232 converter cable
|
|
059728
|
Bracket, Trigger Module
|
|
050242
|
Adapter Connector, Milnor Micro Processor
|
|
027115
|
Water Tempering Valve
|
|
097906
|
Adapter, RS232 to RS485, with Power Supply
|
|
1203286
|
ILS MAX Manual
|
|
068480
|
ILS Tunnel Manual
|
|
|
Spare Parts
|
Code #
|
Description
|
|
096095
|
Strainer kit, manifold
|
|
020948
|
3 ltr (100 oz) peristaltic pump, complete
|
|
096801
|
Transport Pump, complete (ILS MaxT only) (Viton valve/Santoprene diaphragm) 1.65 GPM
|
|
096802
|
Transport Pump, head only (Viton) (ILS MaxT only)
|
|
096803
|
Transport Pump, valve kit (Viton) (ILS MaxT only)
|
|
069947
|
Transport Pump, complete (ILS Max only) (Viton valve/Santoprene diaphragm) 3 GPM
|
|
068636
|
Transport Pump, valve kit (Viton) (ILS Max only)
|
|
1201024
|
Transport Pump, head only, (Viton) (ILS Max only)
|
|
069580
|
Solenoid Valve Repair Kit
|
|
094479
|
Betalink cable, 5 channel, shielded, 22 AWG
|
|
055697
|
Power supply for 097906
|
|
058492
|
Printed circuit board, model 100
|
|
058938
|
Printed circuit board, relay
|
|
1200049
|
Printed circuit board, smart pump, ILS Max (1200090)
|
|
056798
|
Printed circuit board, smart pump, ILS MaxT (068481)
|
|
059948
|
LCD Display
|
|
043969
|
Flowmeter
|
|
051157
|
Probe, CP3411,POD without thermistor
|
|
099905
|
Probe, CP3412, POF with thermistor
|
|
041923
|
Solenoid valve
|
|
042595
|
Float switch, break tank
|
|
056188
|
Washer interface, module only
|
|
050588
|
Harness, machine triggers (striped color)
|
|
099071
|
Float valve
|
|
120317
|
Printed circuit board, model 100 ILS Max T
|
|
098554
|
Barb fittings, 1/2", bag of 2
|
|
055705
|
Straight Fitting, 3/4B x 1/2MPT Polypropylene
|
|
055707
|
Straight Fitting, 1/2B x 1/2MPT Polypropylene
|
|
1200158
|
Fitting 1/2" SH, PVC
|
|
055706
|
Elbow Fitting, 3/4B x 1/2MPT Polypropylene
|
|
041957
|
Tee Fitting, 1/2FPT, PVC
|
|
051301
|
Elbow Fitting, 1/2 x 1/2MPT Polypropylene
|
|
041931
|
Bushing, 1/4FPT x 1/2MPT PVC
|
|
041973
|
Adaptor Fitting, 3/4MGH x 3/8 MPT, Brass
|
|
069946
|
Shurflow Straight Fitting, 1/2 MPT x 1/2 Polypropylene
|
|
|
Component
|
Recommended Qty
|
Code #
|
|
Main Module with 6 each, 3L/min chemical pumps
|
1 each
|
068484
|
|
Break Tank Module
|
1 per system
|
056693
|
|
Transformer, 24 VAC-500 VA
|
1 per system
|
051281
|
|
Auxiliary Pump Box (with 2 each, 3L/min chemical pumps) As required for: 1.
More than 6 chemicals 2. One or more 6L/min chemical pumps
|
|
068482
|
|
"Smart" Transport Module for washer extractors (not for Tunnel
applications)
|
1/2 per washer (2x3 GPM diaphragm per module)
|
1200090
|
|
Washer Interface Kit (includes POD cell assembly)
|
1 per washer
|
056684
|
|
TR-7000 Trigger Module Kit AC/DC with cables (2 trigger modules + 2 harnesses)
|
1 per washer, 1/2 per washer if no datalogging required
|
059011
|
|
Trigger Module (7 channel) AC/DC without cables. As required for: 1. 10 chemicals 2. Formula select above
8 formulas
|
As required
|
059000
|
|
Trigger Enclosure, NEMA type 1
|
As required (1 per washer for mounting of trigger modules external to washer)
|
057279
|
|
Chemical Trigger Harness
|
As required for additional trigger module (above)
|
050587
|
|
FS-1600 Formula Select Module
|
As required for manual formula select
|
091869
|
|
TR-7000 AC Trigger Module without cables
|
As required
|
093126
|
|
ManageNet Win.
|
1 per system
|
099050
|
|
For Tunnel applications use the following component parts:
|
Component
|
Recommended Qty
|
Code #
|
|
Tunnel Kit
|
1 per system
|
068483
|
|
"Smart" Transport Module for Tunnels
|
1/2 per injection point (2 x 1.5 GPM diaphragm per module)
|
068481
|
|
|
|
|