FlowLine® EchoPod® Ultrasonic Level Sensor Technical Specifications Comparison Chart
DL10
DS14
DX10
DL14
DL24
Range:
49.2" (1.25m)
98.4" (2.5m)
Accuracy:
0.125" (3mm)
± 0.2% range
Resolution:
0.019" (0.5mm)
Beam Width:
2" (5cm)
Dead Band:
4" (5cm)
Supply Voltage:
24 VDC (loop)
Loop Resistance:
400ΩO max
Consumption:
0.5W
Signal Output:
4-20mA, two-wire (when loop powered)
None
0-5 V, 0-10 V.976-2000 Hz
Contact Type:
(4) SPST relays 1A
Loop Fail-safety:
4 mA, 20 mA, 21 mA, 22 mA or hold last
Relay Fail-safety:
Power loss: Hold lastPower on: Open, close or hold last
Full, empty, hold last
Hysteresis:
Selectable
Configuration:
WebCal® (PC Windows®)USB 2.0
Temp Comp.:
Automatic over range
Process Temp.:
F: -31° to 140°C: -7° to 60°
F: -21° to 140°C: -7° to 60°
Ambient Temp.:
Pressure:
MWP = 30 PSI
Enclosure:
Type 6P, encapsulated, corrosion resistant & submersible
Encl. Material:
PC/ABS FR
Strain Relief mat.:
Santoprene
Trans. Material:
PVDF
Cable Length:
48" (1.2m)
Cable Jacket Mat.:
Polyurethane
Process Mount:
1" NPT (1" G)
Mount Gasket:
Viton®
Classification:
General Purpose
Approval:
cFMus, CE
Compliance:
RoHS