Specifications
All based on water tests. Results may vary due to varying chemical viscosities or tubing variances
Screen mesh: 200 wires/inch
Spray length, held horizontally: 42" with metal nozzle, 24" with plastic nozzle, 20" if 2 plastic nozzles
Spray diameter, held horizontally:
18" with metal nozzle (20" distance from nozzle), 18" with plastic nozzle (14" distance from nozzle), 10" with 2 plastic nozzles (10" distance from nozzle)
Spray height, pointing up vertically: 38" with metal nozzle, 15" with plastic nozzle, 10" with 2 plastic nozzles
Approximate flow rates: 126 ml/min with metal nozzle & detergent tube, 96 ml/min with plastic nozzle and sanitizer size
tube
Tube life info:
Sanitizer tubes are needed with the plastic nozzles. Detergent tubes may be used if the run time is extremely short, but we do not recommend this since the backpressure will drastically reduce tube life. The detergent tube would, however, rincrease flow by about 20%. Using 2 plastic nozzles will increase pump tube life due to reduced backpressure, and in this case the detergent tube is suitable. With the metal nozzle, a detergent size tube is suitable.
These specifications are subject to change without notice. Specifications for 2 plastic nozzles refer to feeding 2 plastic nozzles from
one DR1000; in the test the transport tube ran about 4' to the "T" tube fitting, and then 28" to the nozzles on each side.
|