Application

The general purpose two-wire ultrasonic transmitter provides non-contact level measurement up to 40' or 12.2m, and is ideally suited for challenging corrosive, coating or waste liquids. The transmitter is broadly selected for atmospheric bulk storage, day tank, process vessel and waste sump applications. Media examples include ink and polymer. See the LU12-14 sensor application matrix for more details.

 

Specifications

 

Range:

LU12: 0.16' to 10' (5 cm to 3m)
LU13: 0.33' to 25' (10 cm to 7.6m)
LU14: 0.66' to 40' (20 cm to 12.2m)

Accuracy:

± 0.15% of span in air

Resolution:

0.125" (3 mm)

Beam width:

LU12: 2" diamater
LU13 or 14: 3" diameter

Dead band:

LU12: 0.16' (5 cm)
LU13: 0.33' (10 cm)
LU14: 0.66' (20 cm)

LED indication:

Power, calibration
and diagnostics

Memory:

Non-volatile

Supply voltage:

14-28 VDC

Loop resist.:

600 Ohms @ 24 VDC

Signal output:

4-20 mA, two-wire

Calibration:

Target, calibration wire

Fail-safety:

Reverts to 22 mA

Process temp.:

F: -40° to 160°
C: -40° to 71°

Temp. comp.:

Automatic

Electronics temp.:

F: -40° to 160°
C: -40° to 71°

Pressure:

30 psi (2 bar) @ 25° C., derated
@ 1.667 psi (.113 bar) per
°C. above 25° C.

Enclosure rating:

NEMA 6X (IP67)

Installed height:

1.7" (4.3 cm) above
tank process mount

Encl. material:

PC/ABS FR

Trans. material:

PVDF Kynar®

Cable jacket mat.:

Polypropylene

Cable type:

3-conductor, shielded

Cable length:

10' (3m)

Process mount:

LU12: 1" NPT (1" G)
LU13 or 14: 2" NPT (2" G)

Mount. gasket:

Viton® (G version only)

Classification:

General purpose

CE compliance:

EN 50082-2 immunity
EN 55011 emission

Click here to download above specifications in a PDF file format.
 

Application Technology

General Purpose

Yes

Conductive

Yes

Non-Conductive

Yes

Δ? Conductive

Yes

Non-contact

Yes

Clean

Yes

Dirty

Yes

Coating

Yes

Non-coating

Yes

Ambient pressure

Yes

Low pressure

Yes

Foam

Consult Factory

Vapors

Consult Factory

Δ? Gas density

Consult Factory

Intrinsically safe

No

Medium pressure

No

Integral Relay

No

Contact

No

Vacuum

No

 